aboutsummaryrefslogtreecommitdiffhomepage
path: root/backends/maweb.md
diff options
context:
space:
mode:
authorcbdev <cb@cbcdn.com>2020-03-23 00:15:00 +0100
committercbdev <cb@cbcdn.com>2020-03-23 00:15:00 +0100
commit37e712edf23a49be5387f945ab9ea57cc0b57f22 (patch)
tree5037b14bdbd08baa8f104f7e4946aa5643281a94 /backends/maweb.md
parent666aec036f9bf0de82c435bd7eace271613cee1e (diff)
parentaa02ccf3abf183207b24fcbb9460cbd904a698e2 (diff)
downloadmidimonster-37e712edf23a49be5387f945ab9ea57cc0b57f22.tar.gz
midimonster-37e712edf23a49be5387f945ab9ea57cc0b57f22.tar.bz2
midimonster-37e712edf23a49be5387f945ab9ea57cc0b57f22.zip
Merge current master
Diffstat (limited to 'backends/maweb.md')
-rw-r--r--backends/maweb.md5
1 files changed, 3 insertions, 2 deletions
diff --git a/backends/maweb.md b/backends/maweb.md
index 45dc778..eddf1a5 100644
--- a/backends/maweb.md
+++ b/backends/maweb.md
@@ -1,7 +1,7 @@
### The `maweb` backend
This backend connects directly with the integrated *MA Web Remote* of MA Lighting consoles and OnPC
-instances (GrandMA2 / GrandMA2 OnPC / GrandMA Dot2 / GrandMA Dot2 OnPC).
+instances (GrandMA2 / GrandMA2 OnPC / Dot2 / Dot2 OnPC).
It grants read-write access to the console's playback controls as well as write access to most command
line and control keys.
@@ -19,6 +19,7 @@ Web Remote. Set a web remote password using the option below the activation sett
| Option | Example value | Default value | Description |
|---------------|-----------------------|-----------------------|---------------------------------------------------------------|
| `interval` | `100` | `50` | Query interval for input data polling (in msec) |
+| `quiet` | `1` | `0` | Turn off some warning messages, for use by experts |
#### Instance configuration
@@ -32,7 +33,7 @@ Web Remote. Set a web remote password using the option below the activation sett
The per-instance command line mode may be one of `remote`, `console` or `downgrade`. The first option handles
command keys with a "virtual" commandline belonging to the Web Remote connection. Any commands entered are
not visible on the main console. The `console` mode is only available with GrandMA2 remotes and injects key events
-into the main console. This mode also supports additional hardkeys that are only available on GrandMA consoles.
+into the main console. This mode also supports additional hardkeys that are only available on GrandMA2 consoles.
When connected to a dot2 console while this mode is active, the use of commandline keys will not be possible.
With the `downgrade` mode, keys are handled on the console if possible, falling back to remote handling if not.